CAMLOG® Titanium bases CAD/CAM

CAMLOG® Titanium bases CAD/CAM for individual fabricated restorations

Custom-made restorations Efficient digital workflow Fully digital to the finished restoration with CAMLOG® Titanium base CAD/CAM - from intraoral scanning with the CAMLOG® Scanbody or CAMLOG® Scanpost through to the fabrication of customized abutments/mesostructures or anatomically shaped individual crowns. New: Titanium base CAD/CAM free – flexible solution for the angled screw channel Axis correction possible up to 25° vertically and 35° horizontally Anti-rotation protection for precise bonding of the ceramic crown Two different chimney heights (4.7 and 6.5 mm) One channel geometry for all implant diameters (except Ø 5.0 mm) Roughened bonding surface Improved esthetics in the anterior tooth region and simplified access to the screw channel in case of limited space If the "captured screw" method is used, make sure that the final abutment screw used for definitive fixation has been inserted before bonding. Patient-friendly scanning option Regardless of system – with the CAMLOG® Scanbody Reusable scanbody Independent of closed manufacturing systems System-specific - with the CAMLOG® Scanpost for the Sirona® Scanbody* Precise fit of the Sirona® Scanbody on the scanpost Integration of the implant into the Sirona® workflow (incl. access to fully compatible material blocks) Chairside fabrication possible Flexible workflows depending on the degree of digitization Burns residue free and can be shortened to a custom length Inner design takes the optimal bonding gap to the titanium base into account for casting or molding techniques Various processing methods: – Scanning a wax-up prepared on the modeling aid – Cast/mold processing of the modeling aid User-friendly processing in the laboratory with the CAMLOG® Bonding aid* Easy to screw by hand with lab analogs Prevents the flow of bonding material into the screw channel when bonding the prosthetic restoration Prevents damage to the screw channel when sandblasting the titanium base CAD/CAM * not for titanium base CAD/CAM free

Article Art.-No. 10 mm CAMLOG® Scanbody** for optical, 3-dimensional localization of CAMLOG® Implants in the mouth or CAMLOG® Lab analogs in the working model, incl. abutment screw, sterile Not compatible with the CEREC and inLab systems from Dentsply Sirona Material PEEK K2610.3310 3.3 mm K2610.3810* 3.8 mm K2610.4310* 4.3 mm K2610.6010* 5.0 mm 6.0 mm CAMLOG® Scanbody multi-use for optical, 3-dimensional localization of CAMLOG® Implants in the mouth or CAMLOG® Lab analogs in the working model, incl. CAMLOG® Abutment screw Not compatible with the CEREC and inLab systems from Dentsply Sirona Material Titanium alloy K2630.3300 3.3 mm K2630.3800 3.8 mm K2630.4300 4.3 mm K2630.6000 5.0 mm 6.0 mm CAMLOG® ScanPost for Sirona® Scanbody for digital recording of the CAMLOG® Implant or lab analog position and for further processing in the CEREC and inLab systems from Dentsply Sirona, incl. abutment screw Material Titanium alloy K2620.3306 3.3 mm K2620.3806* 3.8 mm K2620.4306* 4.3 mm K2620.5006* 5.0 mm K2620.6006* 6.0 mm 10.2 mm Scanbodies and Scanposts * can also be used for Platform Switching ** Please check whether the CAMLOG® Scanbody is available in the CAD software used. CAD libraries for selected CAMLOG® Prosthetic components are available for free download here: Germany: www.camlog.de/cad-bibliotheken Austria: www.alltecdental.at/cad-bibliotheken Switzerland: www.camlog.ch/cad-bibliotheken Matching Sirona® Scanbodies size S for CAMLOG® Scanposts and CAMLOG® Titanium base CAD/CAM, crown, with Ø 3.3/3.8/4.3 mm: For Omnicam®: Article number 6431311 For Bluecam®: Article number 6431295 Matching Sirona® Scanbodies size L for CAMLOG® Scanposts and CAMLOG® Titanium base CAD/CAM, crown, with Ø 5.0/6.0 mm: For Omnicam®: Article number 6431329 For Bluecam®: Article number 6431303 Sirona® Scanbodies are available from Dentsply Sirona. New 10 mm

CAMLOG® Titanium base CAD/CAM CAMLOG® Titanium base CAD/CAM PS CAMLOG® Titanium base free CAD/CAM free CAMLOG® Titanium base free CAD/CAM free PS Description Complete system with titanium base CAD/CAM abutment, modeling aid and bonding aid Complete system with titanium base CAD/CAM abutment, modeling aid and bonding aid in Platform Switching design System-independent titanium base for situations with angled screw channel (vertical angulation up to 25°) System-independent titanium base for situations with angled screw channel (vertical angulation up to 25°) in Platform Switching design Available as crown version a a a a Available as bridge version a a Available in one chimney height (4.7 mm) and one gingival height a a Available in two chimney heights (4.7 and 6.5 mm) and one gingival height a a Can be used in combination with the Sirona® Scanbody for the complete Sirona workflow a a Open system by using CAMLOG® Scanbody a a Can be used with screwdriver, hex a a a a Can be used with ballpoint screwdriver a a CAMLOG® Titanium bases CAD/CAM Overview * not for diameter 3.3 mm ** Must be used with angulated screw-channels *** Must be used with straight screw-channels * * *** ** *** **

Article Art.-No. L Screwdriver hex, extra short, manual/wrench Material Stainless steel J5317.0510 14.5 mm Screwdriver hex, short, manual/wrench Material Stainless steel J5317.0501 22.5 mm Screwdriver hex, long, manual/wrench Material Stainless steel J5317.0502 30.3 mm Screwdriver hex, short, ISO shaft Material Stainless steel J5317.0504 18.0 mm Screwdriver hex, long, ISO shaft Material Stainless steel J5317.0503 26.0 mm Manual screwdriver, hex without wrench head connection Material Stainless steel J5317.0511 23.0 mm Ballpoint screwdriver hex, short, ISO shaft Material Stainless steel J5319.0504* 27 mm Ballpoint screwdriver hex, long, ISO shaft Material Stainless steel J5319.0503* 35 mm Ballpoint screwdriver hex, short, manual/wrench Material Stainless steel J5319.0501 24 mm Ballpoint screwdriver hex, long, manual/wrench Material Stainless steel J5319.0502 32 mm *The ISO shaft is only intended for use with adapters ISO shaft for wrench (J5002.0011)! Ballpoint screwdrivers are only approved for use with the CAMLOG® Titanium base CAD/CAM free. New New New New Product details Screwdriver

Product details Titanium bases CAD/CAM free Article Art.-No. GH 4.7 mm CAMLOG® Titanium base CAD/CAM free, crown, short incl. abutment screw for titanium base CAD/CAM and lab screw Material Titanium alloy K2247.3348* 3.3 mm 0.4 mm K2247.3848 3.8 mm 0.3 mm K2247.4348 4.3 mm K2247.5048 5.0 mm 4.7 mm CAMLOG® Titanium base CAD/CAM free PS, crown, short, for Platform Switching incl. abutment screw for titanium base CAD/CAM and lab screw Material Titanium alloy K2247.3808 3.8 mm 0.8 mm K2247.4308 4.3 mm K2247.5008 5.0 mm 6.5 mm CAMLOG® Titanium base CAD/CAM free, crown, long incl. abutment screw for titanium base CAD/CAM and lab screw Material Titanium alloy K2265.3848 3.8 mm 0.3 mm K2265.4348 4.3 mm K2265.5048 5.0 mm 6.5 mm CAMLOG® Titanium base CAD/CAM free PS, crown, long, for Platform Switching incl. abutment screw for titanium base CAD/CAM and lab screw Material Titanium alloy K2265.3808 3.8 mm 0.8 mm K2265.4308 4.3 mm K2265.5008 5.0 mm *Only for crown restorations in the region of the upper lateral and lower lateral and central incisors PS PS New New New New

Titanium bases CAD/CAM and modeling aid PS Article Art.-No. GH CAMLOG® Titanium base CAD/CAM, crown incl. abutment screw for titanium base CAD/CAM and bonding aid Material Titanium alloy/POM K2244.3348* 3.3 mm 0.4 mm K2244.3848 3.8 mm 0.3 mm K2244.4348 4.3 mm K2244.5048 5.0 mm K2244.6048 6.0 mm CAMLOG® Titanium base CAD/CAM, bridge incl. abutment screw for titanium base CAD/CAM and bonding aid Material Titanium alloy/POM J2344.3348 3.3 mm 0.4 mm J2344.3848 3.8 mm J2344.4348 4.3 mm J2344.5048 5.0 mm J2344.6048 6.0 mm CAMLOG® Titanium base CAD/CAM PS for Platform Switching, crown incl. abutment screw for titanium base CAD/CAM and bonding aid Material Titanium alloy/POM K2210.3808 3.8 mm 0.8 mm K2210.4308 4.3 mm K2210.5008 5.0 mm 11 mm CAMLOG® Modeling aid for CAMLOG® Titanium base CAD/CAM, crown burn-out, for fabricating mesostructures and crowns Material POM J2244.3302 3.3 mm - J2244.3802 3.8 mm J2244.4302 4.3 mm J2244.5002 5.0 mm J2244.6002 6.0 mm *Only for crown restorations in the region of the upper lateral and lower lateral and central incisors The geometries of the CAMLOG® Titanium bases CAD/CAM are available as a CAD library for leading dental CAD systems. The libraries are available for free download at: Germany: www.camlog.de/cad-bibliotheken Austria: www.alltecdental.at/cad-bibliotheken Switzerland: www.camlog.ch/cad-bibliotheken DEDICAM® CAD/CAM prosthetics from Camlog Find out more about DEDICAM® Products at: Germany / Switzerland: Telephone +49 7044 9445-800 | dedicam.cad@camlog.com | www.camlog.de/cadcam Austria: Telephone +43 5572 372341 | info@alltecdental.at | www.alltecdental.at/cadcam 4.7 mm 4 mm 4.7 mm

Rights to changes reserved · M-M-1551-FLY-EN-INT-BHCL-00-122022 Headquarters CAMLOG Biotechnologies GmbH | Margarethenstr. 38 | 4053 Basle | Switzerland Telephone +41 61 565 41 00 | Fax +41 61 565 41 01 | info@camlog.com | www.biohorizonscamlog.com Manufacturer CAMLOG® and CONELOG® Products: ALTATEC GmbH | Maybachstr. 5 | 71299 Wimsheim | Germany CAMLOG® and CONELOG® are registered trademarks of CAMLOG Biotechnologies GmbH.

RkJQdWJsaXNoZXIy MTE0MzMw